ADA Checklist

Contact Arundel Elevator for a complete ADA elevator survey of your elevator plant. We will then furnish you with proposals to upgrade your equipment accordingly.

 

Automatic Operation?

yes___ no___

Leveling Accuracy (+ or - 1/4 inch)?

yes___ no___

Audible signal providing car direction?

yes___ no___

Stop & Alarm Buttons and all emergency controls located at bottom of car station?

yes___ no___

Stop & Alarm Buttons and all emergency controls have their centerlines a minimum of 35" above the floor?

yes___ no___

Car Call Buttons at least 3/4"?

yes___ no___

Car Call Buttons at least 54" above the floor for side approach?

yes___ no___

Car Call Buttons at least 48" above floor for front approach?

yes___ no___

Raised & Braille Tactile Plates:

Hall Buttons?

yes___ no___

Car Buttons And Controls?

yes___ no___

Entrance Frames?

yes___ no___

Hall Buttons centered at 42" above the floor?

yes___ no___

Hall Lanterns:

Visible at each entrance?

yes___ no___

Centerline at least 72" from floor?

yes___ no___

Visual Elements at least 2 1/2"?

yes___ no___

ADA compliant emergency communications provided in car?

yes___ no___

Door Protection:

Doors open and close automatically?

yes___ no___

Safety Shoe protected?

yes___ no___

Double Light Ray protected?

yes___ no___

Illumination of car station, floor & sill at least five (5) foot-candles?

yes___ no___
 

Be sure to consult with your Arundel Elevator Service Representative for further requirements and a more detailed survey of your equipment.

 

 